cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Cable Corp., every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

EPR-CPE (2400V Unshielded) Type MV90 Power Cable - Wet and Dry Location

EPR-CPE 2400V unshielded Type MV-90 power cable combines EPR insulation with a cross-linked CPE jacket for medium voltage power distribution where resistance to moisture, heat, chemicals, and environmental exposure is important. This construction can be a practical choice for industrial and commercial electrical systems that require reliable 2.4kV power cable across a variety of installation conditions.

Custom Cable Corp. supplies EPR-CPE 2400V cable in multiple conductor sizes to help engineers, contractors, and purchasing teams match cable specifications to their electrical and installation requirements. For additional voltage ratings, insulation systems, shielding configurations, and constructions, explore our medium voltage power cable options.

Showing 1–9 of 13 results

Search Part Number
EPR-CPE (2400V Unshielded) Type MV90 Power Cable - Wet and Dry Location

EPR-CPE (2400V Unshielded) Type MV90 Power Cable - Wet and Dry Location

Array
(
    [0] => Application:
  • Where NEC juisdiction applies; as 2,400-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90ºC in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.
  • For use in aerial, conduit, open tray and underground duct installations.
  • Excellent heat and moisture resistance.
  • Low moisture absorption.
  • High dielectric strength.
  • Low dielectric loss.
  • Chemical and sunlight resistant.
  • Meets cold bend test at -35ºC.
[1] => :
  • Where NEC juisdiction applies; as 2,400-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90ºC in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.
  • For use in aerial, conduit, open tray and underground duct installations.
  • Excellent heat and moisture resistance.
  • Low moisture absorption.
  • High dielectric strength.
  • Low dielectric loss.
  • Chemical and sunlight resistant.
  • Meets cold bend test at -35ºC.
[2] => )
Application:
  • Where NEC juisdiction applies; as 2,400-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90ºC in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.
  • For use in aerial, conduit, open tray and underground duct installations.
  • Excellent heat and moisture resistance.
  • Low moisture absorption.
  • High dielectric strength.
  • Low dielectric loss.
  • Chemical and sunlight resistant.
  • Meets cold bend test at -35ºC.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Nominal Weight(LBS/MFT) RFQ
25030 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 6 7 0.125 0.080 0.62 241 Request a Quote
25031 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 4 7 0.125 0.080 0.66 308 Request a Quote
25032 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 2 7 0.125 0.080 0.72 408 Request a Quote
25033 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 1 19 0.125 0.080 0.76 476 Request a Quote
25034 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 1/0 19 0.125 0.080 0.79 562 Request a Quote
25035 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 2/0 19 0.125 0.080 0.84 666 Request a Quote
25036 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 3/0 19 0.125 0.095 0.92 823 Request a Quote
25037 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 4/0 19 0.125 0.095 0.97 983 Request a Quote
25038 Type MV90 - Wet or Dry Unshielded EPR/XL-CPE 2400 Volt 250 37 0.140 0.110 1.08 1183 Request a Quote

Conductor:

  • Class B stranded annealed uncoated copper. Conductors shall be covered with a thermostat semi conduction stress control layer over conductor.

Insulation:

  • EPR (ethylene propylene rubber)

Jacket:

  • Lead free cross-linked chorinated polyethyline (XL-CPE)

Application:

  • Where NEC juisdiction applies; as 2,400-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90ºC in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.
  • For use in aerial, conduit, open tray and underground duct installations.
  • Excellent heat and moisture resistance.
  • Low moisture absorption.
  • High dielectric strength.
  • Low dielectric loss.
  • Chemical and sunlight resistant.
  • Meets cold bend test at -35ºC.

Industry Approvals:

  • Listed by UL as 2,400 volt nonshielded cable, Type MV-90, per UL Standard 1072.
  • Conforms to ICEA S-96-659/NEMA WC71.
  • Sizes 1/0 AWG and larger pass UL and IEEE Standard 383 ribbon burner flame test and are UL listed for CT Use.

Frequently Asked Questions

Yes. This EPR-CPE 2400V Type MV-90 cable is designed for use in wet or dry locations when installed in accordance with its ratings and applicable electrical requirements.

Wet-location suitability can be important in industrial power distribution where cable may be exposed to moisture or installed in environments that are not continuously dry. The cable's EPR insulation and overall construction are designed for these conditions, but the complete installation method and project requirements should always be reviewed before specifying a cable.

The cable's voltage rating must meet the requirements of the electrical system and applicable codes and specifications.

A system's nominal operating voltage is only one consideration when selecting medium voltage cable. Engineers may also need to account for system configuration, grounding, possible overvoltage conditions, equipment requirements, and applicable standards. A 2400V-rated cable should therefore be selected based on the complete electrical design rather than nominal voltage alone.

At minimum, identify the required conductor size, quantity or footage, voltage rating, and any project-specific construction or installation requirements.

Providing complete specifications helps ensure that the quoted cable matches the intended application. It can also be helpful to provide conductor material, installation environment, applicable approvals or standards, required delivery schedule, and any other requirements contained in the project's electrical specifications.

It may be suitable when the specific cable construction and ratings support the environmental conditions encountered along the entire run.

A cable route can pass through several different environments, so selection should be based on the most demanding conditions it will encounter rather than just its starting and ending points. Moisture exposure, sunlight, temperature, routing method, and applicable installation requirements should all be considered when determining whether a particular 2400V EPR-CPE construction is appropriate.

Cable outside diameter affects conduit fill, bending space, pulling requirements, tray capacity, and compatibility with terminations and other installation hardware.

Checking outside diameter before ordering can help prevent installation problems after the cable arrives at the jobsite. This is especially important when an existing raceway, limited equipment space, specific cable glands, or other dimensional constraints are involved. The dimensions of the exact conductor size being ordered should be verified rather than assuming all 2400V cables have similar dimensions.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry

Website Design by PESCE MediaWorks