cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Cable Corp., every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

EPR-PVC (35000V Shielded, Grounded) Type MV-90, Power Cable - 100% Insulation .005 Copper Tape Shield PVC Jacket

For 35kV grounded power distribution systems, EPR-PVC Type MV-90 cable provides a shielded construction combining EPR insulation, a .005-inch copper tape shield, and a protective PVC jacket. This 100% insulation-level cable is designed for demanding medium-voltage installations where dependable dielectric performance and effective shielding are required. Explore our complete selection of medium voltage power cable for additional voltage classes, insulation levels, shielding configurations, and jacket constructions.

Showing 1–9 of 18 results

Search Part Number
EPR-PVC (35000V Shielded, Grounded) Type MV-90, Power Cable - 100% Insulation .005 Copper Tape Shield PVC Jacket

EPR-PVC (35000V Shielded, Grounded) Type MV-90, Power Cable - 100% Insulation .005 Copper Tape Shield PVC Jacket

Array
(
    [0] => Application:
  • Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.
[1] => :
  • Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.
[2] => )
Application:
  • Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Nominal Weight (LBS/MFT) Insulation Type Voltage rating (volts) Shielded RFQ
25310 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 1/0 19 0.345 0.80 1.340 1156 100% EPR 35000 Yes Request a Quote
25311 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 2/0 19 0.345 0.80 1.390 1288 100% EPR 35000 Yes Request a Quote
25312 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 3/0 19 0.345 0.80 1.440 1444 100% EPR 35000 Yes Request a Quote
25313 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 4/0 19 0.345 0.80 1.490 1631 100% EPR 35000 Yes Request a Quote
25314 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 250 37 0.345 0.80 1.540 1801 100% EPR 35000 Yes Request a Quote
25315 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 350 37 0.345 0.80 1.640 2207 100% EPR 35000 Yes Request a Quote
25316 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 500 37 0.345 0.110 1.830 2901 100% EPR 35000 Yes Request a Quote
25317 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 750 61 0.345 0.110 2.030 3919 100% EPR 35000 Yes Request a Quote
25318 EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable 100% Insulation .005 Copper Tape Shield PVC Jacket 1000 61 0.345 0.110 2.190 4864 100% EPR 35000 Yes Request a Quote

Construction

Conductor:

  • Uncoated annealed Class B, concentric compressed round copper strand per ASTM 8.

Conductor Shield:

  • Extruded semiconducting thermosetting compound bonded to the insulation.

Insulation:

  • EPR (Ethylene Propylene Rubber).

Insulation Shield:

  • Thermosetting extruded semiconducting compound applied tightly over the insulation.

Metallic Shield:

  • Uncoated annealed 0.005 inch copper tape shield, helically applied, 12.5% overlap.

Jacket:

  • Black PVC sunlight resistant per ICEA.

Standards:

  • Conductor operating temperatures +90°C continuous, +130°C emergency operation, +250°C short circuit rating. Meets ICEA S-68-516/NEMA WC8. Meets AEIC No. 6 UL 1072 (latest revision).

Application:

  • Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.

Frequently Asked Questions

A .005-inch copper tape shield provides a conductive path around the insulated conductor that helps control the cable's electrical field and supports the grounding of the shielding system.

In a 35kV cable construction, controlling electrical stress becomes particularly important because of the higher operating voltage. The copper tape is applied around the insulation shielding system to create a continuous metallic shield. When properly grounded as part of the engineered electrical system, it helps maintain predictable electrical performance and provides a path for induced and fault-related currents.

EPR insulation is well suited to 35kV cable because it provides strong dielectric properties along with resistance to heat, moisture, and electrical stress.
Ethylene propylene rubber, or EPR, is a thermoset insulation material commonly specified for demanding medium-voltage power distribution. Its electrical and physical properties make it useful in applications where cable may experience elevated temperatures, moisture, changing loads, and long-term electrical stress. For this construction, EPR works together with the shielding system and outer PVC jacket as part of the complete cable design.

The PVC jacket provides an outer protective layer that helps protect the internal cable components from environmental and physical exposure during installation and service.

While EPR provides the primary electrical insulation, the PVC jacket serves a different function. It forms the cable's exterior barrier and helps protect the underlying shielding and insulation system. Jacket selection is therefore an important part of evaluating a medium-voltage cable for its intended installation environment rather than simply choosing a cable based on voltage rating.

The semiconducting insulation shield helps create a uniform electrical interface around the primary insulation, while the copper tape provides the metallic component of the shielding system. Together, these layers help manage the electric field surrounding the conductor. This layered construction is particularly important in higher-voltage cable because small irregularities in electrical stress become more significant as system voltage increases.

Termination involves more than connecting the conductor. The insulation shielding and copper tape shield must be properly addressed so electrical stress is controlled at the point where the cable's shielding system ends. The termination also needs to be compatible with the conductor size and physical dimensions of the specific cable. Because improper preparation can compromise medium-voltage performance, installation and termination should follow the applicable engineering specifications and termination manufacturer's requirements.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry

Website Design by PESCE MediaWorks