Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.
Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.
Medium voltage cable selection is often driven by the installation method as much as the voltage class. This 5kV and 8kV shielded power cable group helps buyers compare conductor size, insulation and jacket thickness, finished diameter, amp ratings by installation type, and cable weight before requesting a quote. Use the table below to match the electrical design, routing method, and project specification for feeder, distribution, branch circuit, utility, or industrial power applications.
Showing 1–9 of 13 results

Medium voltage cable selection is often driven by the installation method as much as the voltage class. This 5kV and 8kV shielded power cable group helps buyers compare conductor size, insulation and jacket thickness, finished diameter, amp ratings by installation type, and cable weight before requesting a quote. Use the table below to match the electrical design, routing method, and project specification for feeder, distribution, branch circuit, utility, or industrial power applications.
| Item # | Item Name | Size (AWG/MCM) | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D. (inches) | Current-Tray (Amps) | Current-Conduit (Amps) | Current-Duct (Amps) | Nominal Weight (LBS/MFT) | RFQ |
| 25051 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 6 | 7 | 0.115 | 0.060 | 0.680 | - | 75 | 85 | 305 | Request a Quote |
| 25052 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 4 | 7 | 0.115 | 0.060 | 0.730 | - | 97 | 110 | 350 | Request a Quote |
| 25053 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 2 | 7 | 0.115 | 0.060 | 0.790 | - | 130 | 145 | 460 | Request a Quote |
| 25054 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 1 | 19 | 0.115 | 0.060 | 0.830 | - | 155 | 170 | 565 | Request a Quote |
| 25055 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 1/0 | 19 | 0.115 | 0.080 | 0.930 | 260 | 180 | 195 | 660 | Request a Quote |
| 25056 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 2/0 | 19 | 0.115 | 0.080 | 0.970 | 300 | 205 | 220 | 770 | Request a Quote |
| 25057 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 3/0 | 19 | 0.115 | 0.080 | 1.020 | 345 | 240 | 250 | 910 | Request a Quote |
| 25058 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 4/0 | 19 | 0.115 | 0.080 | 1.080 | 400 | 280 | 290 | 1055 | Request a Quote |
| 25059 | EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE | 250 | 37 | 0.115 | 0.080 | 1.120 | 445 | 315 | 320 | 1205 | Request a Quote |
Construction
Conductor:
Insulation:
Jacket:
Application:
Approvals:
Shielded medium voltage power cable includes a metallic shield layer around the insulated conductor to help manage electrical stress and support reliable performance in higher-voltage systems. Shielding is commonly specified for medium voltage feeders, distribution circuits, utility systems, plant power, and industrial electrical installations.
The shield construction should match the system voltage, grounding method, installation environment, and project specification.
EPR-PVC medium voltage cable uses EPR insulation with a PVC jacket. EPR insulation is commonly selected for flexibility, electrical performance, and moisture resistance, while the PVC jacket adds an outer protective layer for the cable.
This construction may be used where a project requires shielded medium voltage power cable for feeder, distribution, branch circuit, utility, or industrial applications.
Amp ratings can vary by installation method because cable heat dissipates differently in tray, conduit, and duct environments. A cable installed in tray may have a different allowable ampacity than the same cable installed in conduit or underground duct.
When comparing products, use the amp rating that matches the actual installation method and confirm the final cable size against the project specification or electrical design.
CT use means the cable is suitable for cable tray use when the listed construction and size meet the applicable requirements. On this product group, CT use applies to sizes 1/0 and larger.
If the cable will be installed in tray, buyers should confirm the size, rating, installation conditions, and project specifications before ordering.
To choose the right cable, confirm the voltage class, conductor size, insulation level, shielding requirement, jacket material, installation method, ampacity requirement, and required footage. It is also important to know whether the cable will be installed in tray, conduit, duct, aerial, direct burial, wet location, or dry location conditions.
For quote requests, provide the AWG or MCM size, voltage rating, required length, installation method, and any project or utility specifications.
Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com