Supplier Of Electrical Wire & Cable | Custom Wire and Cable  
  











  




  



















  
      


  
    





Request For Quote

9246, Diesel Locomotive Cable 2000 Volt, 777.7 Get a Quote Today

Conductor:

  • Extra flexible, tinned, annealed, stranded copper per AAR 589 specifications.
    Separator:
  • A suitable separator is used between conductor and insulation.
    Insulation:
  • A compound of vulcanized EP rubber meeting the physical and electrical requirements of ICEA S-68-516.
    Jacket:
  • A Hypalon® jacket meeting the heavy-duty requirements of ICEA S-68-516. We may substitute CPE Jacket.
    Features:
  • 90°C continuous rating
  • Excellent flame resistant - meets IEEE 383 flame test at 70,000 BTU/hr. heat input
  • Can be UL Listed as shipboard cable on special order.
  • Tough and abrasion resistant EP insulation, Hypalon® jacket resistant to oils, grease and gasoline.
  • Extra flexible stranding.
    Applications:
  • Diesel electric locomotives, oil and gas drilling rigs, mining and earth moving equipment, general shipyard use, motor leads, apparatus leads and heavy-duty flexing applications.
    Approvals:
  • U.S. Coast Guard, American Bureau of Shipping for offshore drilling rig use
  • Cables conform to ICEA-NEMA standards, ICEA publication S-68-516.
  • MSHA Approved.

  • AttributeValue
    Item #9246
    Item NameDiesel Locomotive Cable 2000 Volt
    Size (AWG/MCM)777.7
    Strands1925/24
    Nominal O.D. (inches)1.540
    Current (Amps)910
    Nominal Weight(LBS/MFT)3050