Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.
Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.
Custom Cable Corp. offers a variety of MC Cable, with each one designed to meet the needs of business and companies in many industries. Our cable is built from the finest of materials and is designed with superior insulation systems that are unmatched by the competition. All our products are made for real world applications and can hold up to the wear and tear of real world situations. Contact us today to see how our cables can make a difference.
MC cable is commonly used for commercial, industrial, institutional, and construction wiring where conductors need mechanical protection within a metal-clad assembly. It is often selected for feeders, branch circuits, equipment connections, fire alarm systems, and power distribution applications.
MC cable is a metal-clad cable assembly with insulated conductors and a grounding conductor inside a protective metal armor. Armored cable is a broader term that can refer to several cable types with metallic protection, so buyers should confirm the exact cable rating, conductor type, grounding method, and installation approval.
MC cable may be used in certain exposed locations when the cable construction, listing, and installation method meet the applicable code and project requirements. The environment matters, especially if the cable may be exposed to moisture, corrosion, physical damage, or outdoor conditions.
Before ordering Type MC cable, confirm the voltage rating, conductor material, conductor count, ground wire size, armor type, jacket material, shielded or unshielded construction, reel length, and whether the cable is intended for low-voltage, medium-voltage, fire alarm, or power applications.
MC cable is designed to provide mechanical protection while still allowing more routing flexibility than many rigid wiring methods. The actual bend performance depends on armor type, cable diameter, conductor count, jacket construction, and the installation conditions.
Copper provides higher conductivity and more ampacity in a smaller diameter, making it preferred for branch circuits, control wiring, and where space or termination reliability matters. Aluminum is a good choice for large feeders and overhead lines when weight and cost are priorities.
A useful rule of thumb is to upsize aluminum by about two AWG sizes to match copper ampacity, but final sizing must use NEC ampacity tables and account for insulation type, ambient temperature, and voltage drop.
Yes. A common practice is 2/0 AWG copper or 4/0 AWG aluminum for 200 amp residential service conductors, subject to NEC rules, device ratings, and local authority approval. Confirm with code tables for your installation.
Modern alloys and approved connectors reduce many historical issues, but correct termination hardware, installation torque, and devices listed for aluminum are essential. For guidance, see technical testing on aluminum and copper connections.
Showing 1–9 of 18 results

Array ( )
| Item # | Item Name | Size (AWG/MCM) | Ground Wire Size AWG | Reel Length (ft) | Approx Weight / 1000 ft (lbs) | Armor O.D Min. (inches) | Shielded | RFQ |
| 13700 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 115 | 0.410 | No | Request a Quote |
| 13701 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 130 | 0.430 | No | Request a Quote |
| 13702 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 170 | 0.490 | No | Request a Quote |
| 13703 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 190 | 0.510 | No | Request a Quote |
| 13704 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-2 Solid | 16 Bare | 1000 | 130 | 0.420 | No | Request a Quote |
| 13705 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-4 Solid | 16 Bare | 1000 | 155 | 0.440 | No | Request a Quote |
| 13706 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-6 Solid | 16 Bare | 750 | 205 | 0.510 | No | Request a Quote |
| 13707 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-8 Solid | 16 Bare | 750 | 230 | 0.520 | No | Request a Quote |
| 13708 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 14-2 Solid | 14 Green | 1000 | 175 | 0.450 | No | Request a Quote |
MC cable is commonly used for commercial, industrial, institutional, and construction wiring where conductors need mechanical protection within a metal-clad assembly. It is often selected for feeders, branch circuits, equipment connections, fire alarm systems, and power distribution applications.
MC cable is a metal-clad cable assembly with insulated conductors and a grounding conductor inside a protective metal armor. Armored cable is a broader term that can refer to several cable types with metallic protection, so buyers should confirm the exact cable rating, conductor type, grounding method, and installation approval.
MC cable may be used in certain exposed locations when the cable construction, listing, and installation method meet the applicable code and project requirements. The environment matters, especially if the cable may be exposed to moisture, corrosion, physical damage, or outdoor conditions.
Before ordering Type MC cable, confirm the voltage rating, conductor material, conductor count, ground wire size, armor type, jacket material, shielded or unshielded construction, reel length, and whether the cable is intended for low-voltage, medium-voltage, fire alarm, or power applications.
MC cable is designed to provide mechanical protection while still allowing more routing flexibility than many rigid wiring methods. The actual bend performance depends on armor type, cable diameter, conductor count, jacket construction, and the installation conditions.
Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com