Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
At Custom Cable Corp., every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.
Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.
Custom Cable Corp. supplies armored fire alarm cable for fire alarm circuits that need the mechanical protection of a steel armor. Each cable carries dual UL ratings as Type FPLP at 300V and Type MC at 600V, with solid bare copper TFN/THHN conductors, a bare or green ground wire and red galvanized steel armor for easy identification. Choose from 18 constructions from 18 AWG to 12 AWG, including shielded pair versions with an aluminum mylar shield and tinned copper drain wire. The cable is plenum and cable tray rated and passes the UL Steiner Tunnel Test. Browse our full interlocked armored cable selection, or contact our team for a quote.
Showing 1–9 of 18 results

Array
(
[0] => Applications:
| Item # | Item Name | Size (AWG/MCM) | Ground Wire Size AWG | Reel Length (ft) | Approx Weight / 1000 ft (lbs) | Armor O.D Min. (inches) | Shielded | RFQ |
| 13700 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 115 | 0.410 | No | Request a Quote |
| 13701 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 130 | 0.430 | No | Request a Quote |
| 13702 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 170 | 0.490 | No | Request a Quote |
| 13703 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 18-2 Solid | 18 Bare | 1000 | 190 | 0.510 | No | Request a Quote |
| 13704 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-2 Solid | 16 Bare | 1000 | 130 | 0.420 | No | Request a Quote |
| 13705 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-4 Solid | 16 Bare | 1000 | 155 | 0.440 | No | Request a Quote |
| 13706 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-6 Solid | 16 Bare | 750 | 205 | 0.510 | No | Request a Quote |
| 13707 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 16-8 Solid | 16 Bare | 750 | 230 | 0.520 | No | Request a Quote |
| 13708 | Armored Fire Alarm Cable- UL (FPLP) 300V, (MC) 600V | 14-2 Solid | 14 Green | 1000 | 175 | 0.450 | No | Request a Quote |
Construction
Conductor:
Insulation:
Assembly Covering:
Shield:
Maximum Temperature Rating:
Ground Wire:
Armor:
Maximum Voltage:
Approvals:
Applications:
It means the same cable is listed as Type FPLP power limited fire alarm cable at 300V and as Type MC metal clad cable at 600V, so it can be used under either NEC article.
FPLP is the plenum grade of power limited fire alarm cable covered by NEC Article 760, and MC is metal clad cable covered by NEC Article 330. A cable listed both ways gives designers flexibility: it can run power limited fire alarm circuits at up to 300V, or serve as MC cable at up to 600V for circuits such as remote control of motor starters, contactors and relays. The temperature rating also differs by listing, at 105°C dry for FPLP and 90°C dry for MC on this cable. Confirm which listing applies to your circuit with the system designer and the authority having jurisdiction.
The red color code on the galvanized steel armor identifies the cable as fire alarm wiring at a glance.
In buildings with many armored cables, color coding helps installers, inspectors and maintenance crews tell circuits apart without tracing them. Red is the color widely used to identify fire alarm circuits, and many local codes and specifications call for fire alarm wiring to be identified this way. On this cable the red spiral color code is applied to the galvanized steel armor, so the identification runs the full length of the cable. Check your project specification and local code for any added labeling requirements.
Yes. This cable passes the UL Steiner Tunnel Test and is plenum rated, so it can be used in ducts, plenums and other environmental air spaces as permitted by the NEC.
Spaces used for environmental air require cable that limits flame spread and smoke, which is what the UL 910 Steiner Tunnel Test measures. This cable passes that test and lists NEC 300.22(C) among its approvals, the section that covers wiring in other spaces used for environmental air. It is also listed for exposed and concealed work, cable trays and ducts. Installation details such as support spacing and fittings still need to meet the code edition in force, so confirm with the authority having jurisdiction.
Yes, within limits. It is listed for Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations as specified in NEC Articles 501, 502 and 503.
Hazardous locations are classified by the type of material present: Class I for flammable gases and vapors, Class II for combustible dust and Class III for ignitable fibers. Division 2 generally covers areas where the hazard is present only under abnormal conditions. This cable is listed for Class I and II, Division 2 and for Class III, Division 1 and 2, as stated in its approvals. Division 1 Class I and II locations are not part of that listing, and fittings and terminations must also suit the location, so review the area classification with the engineer of record before ordering.
It means the cable has been rated for use in 1, 2 and 3-hour through penetration firestop systems in fire rated walls.
When cable passes through a fire rated wall or floor, the opening has to be sealed with a firestop system that keeps the assembly's hourly rating. This cable is rated for 1, 2 and 3-hour through penetration fire wall applications. The rating applies to the tested firestop system as a whole, including the sealant or device and the opening size, so the installer should follow a listed firestop system that names this type of cable. Verify the system details with the firestop manufacturer and the authority having jurisdiction.