cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

XLP Power Cable- 5,000V (Unshielded) Type MV-90

Search Part Number
XLP Power Cable- 5,000V (Unshielded) Type MV-90

XLP Power Cable- 5,000V (Unshielded) Type MV-90

Array
(
    [0] => Application:
  • Where NEC jurisdiction applies as 5,000 volt non-shielded power cable, Type MV-90 Dry, for use at conductor temperatures not exceeding 90°C in dry locations. Cables meet requirements of Article 310-6 of the NEC.
  • For other applications, as non-shielded power cables for use at 5000 volts 100% insulation level (common system voltage 4160 volts) or 3000 volts 133% insulation level (common system voltage 2400 volts), under the following conditions:
    1. Single conductors mounted on insulators in free air in indoor or outdoor locations.
    2. Random lay singles in metal conduit or triplexed singles in non-metallic conduit, above grade, in dry locations.
    3. Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations.
    4. Triplexed singles in trays, in spaced block supports or in messenger supported rings, indoors above grade in dry locations.
[1] => :
  • Where NEC jurisdiction applies as 5,000 volt non-shielded power cable, Type MV-90 Dry, for use at conductor temperatures not exceeding 90°C in dry locations. Cables meet requirements of Article 310-6 of the NEC.
  • For other applications, as non-shielded power cables for use at 5000 volts 100% insulation level (common system voltage 4160 volts) or 3000 volts 133% insulation level (common system voltage 2400 volts), under the following conditions:
    1. Single conductors mounted on insulators in free air in indoor or outdoor locations.
    2. Random lay singles in metal conduit or triplexed singles in non-metallic conduit, above grade, in dry locations.
    3. Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations.
    4. Triplexed singles in trays, in spaced block supports or in messenger supported rings, indoors above grade in dry locations.
[2] => )
Application:
  • Where NEC jurisdiction applies as 5,000 volt non-shielded power cable, Type MV-90 Dry, for use at conductor temperatures not exceeding 90°C in dry locations. Cables meet requirements of Article 310-6 of the NEC.
  • For other applications, as non-shielded power cables for use at 5000 volts 100% insulation level (common system voltage 4160 volts) or 3000 volts 133% insulation level (common system voltage 2400 volts), under the following conditions:
    1. Single conductors mounted on insulators in free air in indoor or outdoor locations.
    2. Random lay singles in metal conduit or triplexed singles in non-metallic conduit, above grade, in dry locations.
    3. Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations.
    4. Triplexed singles in trays, in spaced block supports or in messenger supported rings, indoors above grade in dry locations.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal O.D. (inches) Current-Conduit (Amps) Currentair amps Nominal Weight (LBS/MFT) Current conduit amps Current air amps RFQ
13400 XLP Power Cable- 5,000V (Unshielded) Type MV-90 8 7 0.110 0.390 55 83 90 55 83 Request a Quote
13401 XLP Power Cable- 5,000V (Unshielded) Type MV-90 6 7 0.110 0.420 75 110 125 75 110 Request a Quote
13402 XLP Power Cable- 5,000V (Unshielded) Type MV-90 4 7 0.110 0.470 97 145 180 97 145 Request a Quote
13403 XLP Power Cable- 5,000V (Unshielded) Type MV-90 2 7 0.110 0.530 130 190 260 130 190 Request a Quote
13404 XLP Power Cable- 5,000V (Unshielded) Type MV-90 1 19 0.110 0.560 155 225 325 155 225 Request a Quote
13405 XLP Power Cable- 5,000V (Unshielded) Type MV-90 1/0 19 0.110 0.600 180 260 400 180 260 Request a Quote
13406 XLP Power Cable- 5,000V (Unshielded) Type MV-90 2/0 19 0.110 0.650 205 300 490 205 300 Request a Quote
13407 XLP Power Cable- 5,000V (Unshielded) Type MV-90 3/0 19 0.110 0.700 240 345 600 240 345 Request a Quote
13408 XLP Power Cable- 5,000V (Unshielded) Type MV-90 4/0 19 0.110 0.750 280 400 745 280 400 Request a Quote

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry