cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Overhead Distribution Cable, Weather Proof Line Wire

Overhead distribution weather-proof line wire is designed for outdoor electrical distribution where the conductor requires added protection from exposure to the elements. Available with solid or stranded copper conductors and a durable HMWPE covering, it is suited for utility and distribution applications that require dependable performance in exposed environments.

Explore additional conductor options in our full selection of Bare Copper and Weather-Proof Wire.

Showing 1–9 of 15 results

Search Part Number
Overhead Distribution Cable, Weather Proof Line Wire

Overhead Distribution Cable, Weather Proof Line Wire

Array
(
    [0] => Applications:
  • For use in overhead distribution systems where protection from environmental elements is required.
[1] => s:
  • For use in overhead distribution systems where protection from environmental elements is required.
[2] => )
Applications:
  • For use in overhead distribution systems where protection from environmental elements is required.

Item # Item Name Size (AWG/MCM) Strands Covering Thickness (inches) Nominal O.D. (inches) Dc resistance per 100 ft at 20 °chard drawn Dc resistance per 100 ft at 20 °c medium hard drawn DC Resistance per 100 ft at 20 °C- Soft (Annealed) Drawn Current (Amps) Nominal Weight (LBS/MFT) RFQ
29600 Overhead Distribution Cable- Weather Proof Line Wire 6 Solid 0.030 0.220 0.4110 ohms 0.4088 ohms 0.3952 ohms 130 87 Request a Quote
29602 Overhead Distribution Cable- Weather Proof Line Wire 4 Solid 0.030 0.260 0.2584 ohms 0.2571 ohms 0.2485 ohms 163 135 Request a Quote
29604 Overhead Distribution Cable- Weather Proof Line Wire 4 7 0.030 0.290 0.2636 ohms 0.2622 ohms 0.2540 ohms 163 139 Request a Quote
29606 Overhead Distribution Cable- Weather Proof Line Wire 2 Solid 0.045 0.350 0.1625 ohms 0.1617 ohms 0.1563 ohms 219 218 Request a Quote
29608 Overhead Distribution Cable- Weather Proof Line Wire 2 7 0.045 0.380 0.1660 ohms 0.1650 ohms 0.1590 ohms 219 224 Request a Quote
29610 Overhead Distribution Cable- Weather Proof Line Wire 1 7 0.045 0.420 0.1316 ohms 0.1309 ohms 0.1265 ohms 258 284 Request a Quote
29612 Overhead Distribution Cable- Weather Proof Line Wire 1/0 7 0.060 0.490 0.1042 ohms 0.1037 ohms 0.1002 ohms 297 358 Request a Quote
29614 Overhead Distribution Cable- Weather Proof Line Wire 2/0 7 0.060 0.530 0.0826 ohms 0.0822 ohms 0.0795 ohms 344 446 Request a Quote
29616 Overhead Distribution Cable- Weather Proof Line Wire 3/0 7 0.060 0.580 0.0655 ohms 0.0652 ohms 0.0630 ohms 401 557 Request a Quote

Description:

  • Copper conductor, solid or stranded, soft (annealed), medium hard, or hard drawn, covered with black high molecular weight polyethylene (HMWPE)

Applications:

  • For use in overhead distribution systems where protection from environmental elements is required.

Standards:

  • Line wire conforms to ASTM standards:
    1. B-1 (Hard Drawn).
    2. B-2 (Medium Hard Drawn).
    3. B-3 (Soft or Annealed).
    4. B-8 (Concentric Stranded Copper).
    5. Line wire conforms to ANSI C8.35

Frequently Asked Questions

No. Weather-proof line wire has a protective covering, but that covering should not automatically be treated as electrical insulation.
The polyethylene covering helps protect the copper conductor from weather and environmental exposure in overhead distribution applications. However, covered conductors and fully insulated conductors are not interchangeable terms. The installation design, voltage, clearances and applicable electrical requirements should determine whether a particular conductor is appropriate.

Hard-drawn copper is typically selected when greater mechanical strength is important.
Copper temper affects both mechanical and electrical characteristics. Hard-drawn copper offers greater tensile strength, which can be useful for overhead conductors that must support mechanical loading. Soft annealed copper is more flexible and generally offers slightly lower electrical resistance. The appropriate temper depends on the installation and performance requirements.

Yes. Stranded conductors are generally more flexible than solid conductors of comparable size.
That added flexibility can make stranded line wire easier to route, terminate or handle during installation. Solid conductors provide a simpler construction and may be appropriate where flexibility is less important. Conductor size, span, mechanical loading and termination requirements should all be considered before selecting between solid and stranded construction.

Selection should be based on electrical load, conductor resistance, installation conditions and system requirements, not size alone.
Larger conductors generally provide greater current-carrying capability and lower resistance, but the correct choice also depends on allowable voltage drop, span length, conductor temperature and the requirements of the distribution system. The product specifications should be compared carefully before selecting a conductor for a particular project.

No. The covering does not eliminate the need to follow proper clearances and installation requirements.
Weather-resistant covering provides environmental protection, but an overhead distribution system still has to be designed around appropriate conductor spacing, supports, voltage class and applicable utility or electrical standards. The presence of HMWPE covering should not be used as a reason to reduce required clearances or treat the conductor as touch-safe.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry