cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Overhead Distribution Copper Cable Service Drop

Showing 1–9 of 21 results

Search Part Number
Overhead Distribution Copper Cable Service Drop

Overhead Distribution Copper Cable Service Drop

Array
(
)
Conductors Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. Neutral is solid or stranded, bare hard drawn copper.

Item # Item Name Code Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Neutral Messenger- Hard Drawn size (AWG) Neutral Messenger- Strand (AWG) Current (Amps) Nominal Weight (LBS/MFT) Voltage rating (volts) RFQ
29500 Overhead Distribution Copper Cable Service Drop Bodoni 8 7 0.045 8 1 66 185 600 Request a Quote
29502 Overhead Distribution Copper Cable Service Drop Garamond 8 7 0.045 8 7 66 185 600 Request a Quote
29504 Overhead Distribution Copper Cable Service Drop Futura 6 7 0.045 6 1 89 281 600 Request a Quote
29506 Overhead Distribution Copper Cable Service Drop Gothic 6 7 0.045 6 7 89 281 600 Request a Quote
29508 Overhead Distribution Copper Cable Service Drop Ionic 4 7 0.045 4 1 117 435 600 Request a Quote
29510 Overhead Distribution Copper Cable Service Drop Caslon 4 7 0.045 4 7 117 435 600 Request a Quote
29512 Overhead Distribution Copper Cable Service Drop Century 2 7 0.045 2 7 158 677 600 Request a Quote
29514 Overhead Distribution Copper Cable Service Drop Corinthian 1/0 19 0.055 1/0 7 214 1042 600 Request a Quote
29516 Overhead Distribution Copper Cable Service Drop Doric 2/0 19 0.055 2/0 7 247 1315 600 Request a Quote

Conductors
Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. Neutral is solid or stranded, bare hard drawn copper.

Description:

  • The conductors are Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. The neutral is solid or stranded, bare hard drawn copper

Industry Approvals:

  • ASTM B-1 (Hard Drawn).
  • ASTM B-3 (Soft Drawn or Annealed).
  • ASTM B-8 (Concentric-lay strand).
  • ICEA S66-524.
  • Conductor rated at 90° C

Frequently Asked Questions

Copper service drop cable may be specified when the project requires higher conductivity, compatibility with copper service equipment, reduced conductor diameter, or a utility-approved copper conductor for the overhead service connection.

Conductor material affects current capacity, cable weight, connection requirements, voltage drop, and long-term compatibility with terminals or service equipment. Copper and aluminum service drop cables should not be treated as direct one-for-one substitutions without checking the full project requirements.

Important conditions include span length, exposure to weather, service load, point of attachment, clearance requirements, conductor configuration, and the equipment or utility standard that governs the service connection.

Yes, copper service drop cable may be used for replacement service work when it matches the existing system requirements, utility rules, service rating, and connection equipment. The replacement cable should be selected based on the full service design, not only the previous cable size.

Buyers should provide the service type, conductor size, number of conductors, voltage rating, span details, required length, utility specification if available, and whether the cable is for a new overhead service, replacement service, or project-specific distribution connection.