cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V

Showing 1–9 of 16 results

Search Part Number
Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V

Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V

Array
(
    [0] => Applications:
  • For lighting and power applications in accordance with the NEC and for other general purpose wiring applications. Suitable for use in circuits not exceeding 600 volts at conductor temperatures not exceeding 90°C in wet or dry locations. May be installed in raceway, duct, cable tray, direct burial and aerial installations.
[1] => s:
  • For lighting and power applications in accordance with the NEC and for other general purpose wiring applications. Suitable for use in circuits not exceeding 600 volts at conductor temperatures not exceeding 90°C in wet or dry locations. May be installed in raceway, duct, cable tray, direct burial and aerial installations.
[2] => )
Applications:
  • For lighting and power applications in accordance with the NEC and for other general purpose wiring applications. Suitable for use in circuits not exceeding 600 volts at conductor temperatures not exceeding 90°C in wet or dry locations. May be installed in raceway, duct, cable tray, direct burial and aerial installations.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Current (amps)90°C USE-2RHW-2 RHH Current (amps)75°C USE-2RHH Current (amps)90°C USE-2RHW-2 Nominal Weight (LBS/MFT) RFQ
34003 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 12 7 0.030 0.015 0.200 30 25 - 35 Request a Quote
34005 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 10 7 0.030 0.015 0.220 40 35 - 50 Request a Quote
34007 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 8 7 0.045 0.015 0.290 55 50 - 80 Request a Quote
34008 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 6 7 0.045 0.030 0.350 75 65 - 125 Request a Quote
34009 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 4 7 0.045 0.030 0.390 95 85 - 180 Request a Quote
34011 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 2 7 0.045 0.030 0.460 130 115 - 270 Request a Quote
34012 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 1 19 0.055 0.045 0.550 150 130 - 360 Request a Quote
34013 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 1/0 19 0.055 0.045 0.590 170 150 169 435 Request a Quote
34014 Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V 2/0 19 0.055 0.045 0.640 195 175 195 530 Request a Quote

Construction

Conductor:

  • Annealed coated copper conductor.

Insulation:

  • EPR (ethylene-propylene-rubber)

Jacket:

  • HYPALON® surface printed

Applications:

  • For lighting and power applications in accordance with the NEC and for other general purpose wiring applications. Suitable for use in circuits not exceeding 600 volts at conductor temperatures not exceeding 90°C in wet or dry locations. May be installed in raceway, duct, cable tray, direct burial and aerial installations.

Industry Approvals:

  • UL Listed as type USE-2 (90°C wet or dry) per standard 854 for service entrance cables.
  • UL Listed as types RHW-2 (90°C wet or dry) or RHH (90°C dry) per standard 44.
  • All sizes carry the VW-1 flame test designation.
  • Cables are UL listed as sunlight resistant (1/0 AWG and larger).
  • Size 1/0 AWG and larger pass UL and IEEE-383 ribbon burner flame test and are UL listed for CT use.
  • Conforms to ICEA Pub. No. S-68-516/NEMA WC8 for ethylene propylene-rubber insulated cable.
  • Conforms to Federal Specification J-C-30B.

Frequently Asked Questions

Type USE-2 EPR/HYP building wire is used for underground service entrance, feeder, lighting, power, and general-purpose wiring applications in circuits rated up to 600 volts.

Yes. Type USE-2 wire is designed for underground service entrance applications and may be used for direct burial when installed according to code, project specifications, and the required installation conditions.

EPR refers to ethylene propylene rubber insulation, and HYP refers to a hypalon-style protective jacket. This construction is used when the wire needs dependable insulation performance and added protection in demanding environments.

USE-2 EPR/HYP uses rubber-based insulation with a protective jacket, while USE-2 XLP uses cross-linked polyethylene insulation. The best choice depends on the application, installation environment, flexibility needs, and project specifications.

The right wire depends on conductor size, copper or aluminum requirements, voltage rating, insulation and jacket construction, wet-location needs, underground installation conditions, and applicable electrical code requirements.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry