cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Cable Corp., every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Service Entrance Type SE, Style U, Copper, 600V

Custom Cable Corp. supplies Type SE Style U copper cable for above-ground service entrance and branch circuit runs. Each construction uses fully annealed class B copper conductors, with color-coded PVC plus nylon insulation on the phase conductors per UL 83 for Type THHN/THWN, an uninsulated concentric neutral served around the parallel phase conductors, fiberglass reinforced binder tape, and a sunlight and moisture resistant, flame retardant gray PVC jacket. The phase conductors are identified black and red. Choose from 13 constructions from 8/2 through 3/0-2, in full or reduced neutral, rated 90°C in dry locations or 75°C in wet locations and 600 volts. Browse our full building wire selection, or contact our team for a quote.

Showing 1–9 of 13 results

Search Part Number
Service Entrance Type SE, Style U, Copper, 600V

Service Entrance Type SE, Style U, Copper, 600V

Array
(
    [0] => Application:
  • Above ground service entrance and branch circuit.
  • Maximum operating temperature of phase conductors not to exceed 90°C for dry locations or 75°C for wet locations.
  • 600 volts, approved for use as specified by the NEC®.
[1] => :
  • Above ground service entrance and branch circuit.
  • Maximum operating temperature of phase conductors not to exceed 90°C for dry locations or 75°C for wet locations.
  • 600 volts, approved for use as specified by the NEC®.
[2] => )
Application:
  • Above ground service entrance and branch circuit.
  • Maximum operating temperature of phase conductors not to exceed 90°C for dry locations or 75°C for wet locations.
  • 600 volts, approved for use as specified by the NEC®.

Item # Item Name Size (AWG/MCM) Strands Ground Wire Size AWG Overall Diameter (inches) Shipping Weight (LBS/MFT) RFQ
15280 Service Entrance Type SE, Style U- Copper, 600V 8/2 7 8 0.38 x 0.67 230 Request a Quote
15281 Service Entrance Type SE, Style U- Copper, 600V 6/2 7 8 0.42 x 0.74 302 Request a Quote
15282 Service Entrance Type SE, Style U- Copper, 600V 6/2 7 6 0.42 x 0.74 333 Request a Quote
15283 Service Entrance Type SE, Style U- Copper, 600V 4/2 7 6 0.47 x 0.84 438 Request a Quote
15284 Service Entrance Type SE, Style U- Copper, 600V 4/2 7 4 0.48 x 0.85 486 Request a Quote
15285 Service Entrance Type SE, Style U- Copper, 600V 3/2 7 5 0.51 x 0.91 554 Request a Quote
15286 Service Entrance Type SE, Style U- Copper, 600V 3/2 7 3 0.53 x 0.92 615 Request a Quote
15287 Service Entrance Type SE, Style U- Copper, 600V 2/2 7 4 0.54 x 0.97 684 Request a Quote
15288 Service Entrance Type SE, Style U- Copper, 600V 2/2 7 2 0.56 x 0.99 759 Request a Quote

Construction

Conductor:

  • Fully annealed class B copper per ASTM B-3 and ASTM B-8 or B-787.

Insulation:

  • Color coded PVC (polyvinyl chloride) with a nylon jacket per UL 83 for Type THHN/THWN.

Conductor Identification:

  • Base colored insulation black and red.

Bare Conductor:

  • Uninsulated concentric neutral served around parallel phase conductors.

Tape:

  • Fiberglass reinforced binder tape.

Jacket:

  • Gray PVC (polyvinyl chloride).

Application:

  • Above ground service entrance and branch circuit.
  • Maximum operating temperature of phase conductors not to exceed 90°C for dry locations or 75°C for wet locations.
  • 600 volts, approved for use as specified by the NEC®.

Features:

  • Color coded phase conductors.
  • Full or reduced neutral constructions.
  • Fiberglass reinforced tape under the outer jacket.
  • Sunlight and moisture resistant, flame retardant jacket.

Industry Approvals:

  • UL Standard 854.
  • Federal Specification JC-30B
  • NEC® Articles 230, 310 and 338 (NFPA 70).

Packaging:

  • 500 ft. reels

Frequently Asked Questions

Style U on this page uses an uninsulated concentric neutral served around the parallel phase conductors, under a gray PVC jacket.

That concentric neutral is served around the phase conductors, which run parallel rather than being cabled into a round assembly. The product table lists overall diameter as two dimensions, from 0.38 x 0.67 inch on the 8/2 cable (item 15280) to 0.81 x 1.37 inch on the 3/0-2 cable (item 15292). The phase conductors are identified black and red, and the features include full or reduced neutral constructions. If a specification calls for Style R, that is a different service entrance construction than the Style U items listed here.

Yes. The phase conductors are rated 90°C in dry locations or 75°C in wet locations, at 600 volts, for use as specified by the NEC.

The application on this page is above-ground service entrance and branch circuit. The gray PVC jacket is sunlight and moisture resistant and flame retardant. The cable is listed to UL Standard 854 and to Federal Specification JC-30B, and it is approved for use as specified by NEC Articles 230, 310, and 338. Follow the NEC and the project specification for the installation method and terminations, and confirm any special conditions with the authority having jurisdiction.

A full neutral is the same size as the phase conductors, and a reduced neutral is smaller. The 6/2, 4/2, 3/2, and 2/2 sizes on this page come both ways.

The product table lists the bare conductor size in its Ground Wire Size column. On the 6/2, 4/2, 3/2, and 2/2 sizes, two sizes are listed for the same phase size, one reduced and one full. For example, 6/2 is offered with an 8 AWG ground (item 15281) or a 6 AWG ground (item 15282), 4/2 with a 6 AWG or 4 AWG ground, 3/2 with a 5 AWG or 3 AWG ground, and 2/2 with a 4 AWG or 2 AWG ground. The 8/2, 1/2, 1/0-2, 2/0-2, and 3/0-2 items are each listed with one ground wire size that matches the phase size. The construction identifies that bare conductor as an uninsulated concentric neutral served around the parallel phase conductors. Choose the ground wire size that matches the project specification, and request a quote for the item number you need.

This page lists 13 constructions from 8/2 through 3/0-2 copper, with 7-strand sizes through 2/2 and 19-strand sizes from 1/2 through 3/0-2.

The product table covers items 15280 through 15292. Overall diameter and shipping weight increase with size, from 0.38 x 0.67 inch and 230 lb/MFT on the 8/2 cable (item 15280) to 0.81 x 1.37 inch and 1,800 lb/MFT on the 3/0-2 cable (item 15292). All 13 items are named as Service Entrance Type SE, Style U, copper, 600V. Packaging is 500 ft. reels. Choose the size and ground wire size that match the load and the project specification, and request a quote for the item number you need.

The phase conductors have color-coded PVC insulation with a nylon jacket per UL 83 for Type THHN/THWN, and the cable has a gray PVC jacket that is sunlight and moisture resistant and flame retardant.

The phase conductors are identified black and red. A fiberglass reinforced binder tape sits under the outer jacket. The 90°C dry and 75°C wet temperature limits apply to the phase conductors, and the cable is listed to UL Standard 854 as Type SE, at 600 volts. If a specification calls for a different insulation system or a single-conductor building wire rather than a Type SE assembly, that would be a different product family than the Style U items listed here.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry

Website Design by PESCE MediaWorks