cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Neoprene Flat Festoon Cable, 50°C TO 90°C, UL AND CSA - 600V

Neoprene flat festoon cable is built for moving industrial equipment that requires dependable power or control connections through repeated travel and flexing. Its flat configuration helps keep cable routing organized in compact festoon systems, while the neoprene jacket makes it a practical choice for demanding environments where durability, movement and exposure conditions all need to be considered when selecting cable. For additional constructions and applications, explore our full selection of control cable options.

Showing 1–9 of 16 results

Search Part Number
Neoprene Flat Festoon Cable, 50°C TO 90°C, UL AND CSA - 600V

Neoprene Flat Festoon Cable, 50°C TO 90°C, UL AND CSA - 600V

Applications:

  • Primarily designed for use with festoon systems for the conveyance of electrical power and control to cranes, hoists, or any equipment which travels with a lateral transversing motion. Festoon Cables can also be used where space is at a premium, since it can be stacked or where extreme flexing is a requirement, recommended bend radius of three to five times cable diameter. Neoprene Festoon Cables are suitable for either indoor or outdoor applications operating at -50°C to 90° C.Features:
  • Easy stripping.
  • Easy stacking of multiple cables in smaller space.
  • Enhanced stability in outdoor applications against crosswinds.
  • Maintains cable integrity.
  • Reduces conductor stress and increases …

Item # Item Name Size (AWG/MCM) No. of Conductors Strands Nominal Insulation Thickness (inches) Nominal O.D. (inches) Current (Amps) Nominal Weight (LBS/MFT) No conductors RFQ
39445 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 16 8 26/30 0.030 0.245 x 1.195 14 226 8 Request a Quote
39446 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 16 12 26/30 0.030 0.245 x 1.730 14 330 12 Request a Quote
39450 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 14 4 41/30 0.045 0.295 x 0.865 18 191 4 Request a Quote
39451 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 14 8 41/30 0.045 0.295 x 1.610 16 361 8 Request a Quote
39452 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 14 12 41/30 0.045 0.295 x 2.355 16 531 12 Request a Quote
39460 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 12 4 65/30 0.045 0.315 x 0.945 23 242 4 Request a Quote
39461 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 12 8 65/30 0.045 0.315 x 1.770 20 461 8 Request a Quote
39463 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 10 4 105/30 0.045 0.340 x 1.045 29 312 4 Request a Quote
39465 Neoprene Flat Festoon Cable -50°C TO 90°C - UL AND CSA - 600V 8 4 168/30 0.060 0.450 x 1.405 41 552 4 Request a Quote

Construction

Conductor:

  • Extra flexible stranding, soft drawn uncoated copper per ASTM B-33, ASTM B-174, UL-62.

Insulation:

  • Color coded, Thermoset (EPDM) insulation, colored or printed for easy conductor identification.

Jacket:

  • Black, oil and flame resistant. Thermoset (Neoprene) jacket.

Applications:

  • Neoprene Festooning Cable is primarily designed for use with festoon systems for the conveyance of electrical power and control to cranes, hoists, or any equipment which travels with a lateral transversing motion. Festoon Cables can also be used where space is at a premium, since it can be stacked or where extreme flexing is a requirement, recommended bend radius of three to five times cable diameter. Neoprene Festoon Cables are suitable for either indoor or outdoor applications operating at -50°C to 90° C.

Features:

  • Easy stripping.
  • Easy stacking of multiple cables in smaller space.
  • Enhanced stability in outdoor applications against crosswinds.
  • Maintains cable integrity.
  • Reduces conductor stress and increases Flex-Life.
  • Easy jacket stripping.

Industry Approvals:

  • UL Listed and CSA certified 600 volts -50° C to 90° C.

Frequently Asked Questions

Flat cable helps conductors move in a controlled path while keeping the cable package compact.

In a festoon system, multiple cables may need to travel together as equipment moves. A flat construction can help organize those cables, limit twisting and make more efficient use of the available carrier or trolley space. The final cable arrangement should still account for conductor count, cable dimensions, travel distance and the mechanical design of the festoon system.

The conductor count should match the number of power and control circuits required by the moving equipment.

A crane, hoist or other traveling machine may require conductors for motor power, controls, limit switches, brakes or auxiliary functions. The system wiring diagram should be used to determine the required conductor count, along with conductor size and current requirements. Choosing the cable from the electrical design helps avoid unnecessary conductors or an undersized configuration.

Neoprene is used because it combines flexibility with resistance to several types of physical and environmental stress.

In moving industrial applications, the outer jacket is repeatedly bent and exposed to handling, abrasion and surrounding operating conditions. A neoprene jacket can provide a durable protective layer while allowing the cable to flex as the equipment travels. The specific cable rating should always be checked against the actual temperature, oil, moisture and mechanical conditions of the installation.

Yes, provided the cable and festoon system are designed for the required motion and flexing cycle.

Repeated directional movement places mechanical stress on conductors and jackets, particularly when travel cycles are frequent. Cable selection should consider flex life, conductor construction, bend radius, cable support and trolley spacing. Proper system design is important because even a flexible cable can experience premature wear if it is forced into excessive bending or poor alignment.

Match more than just the voltage and conductor count.

A replacement should be evaluated for conductor size, number of conductors, cable dimensions, temperature rating, current requirements, jacket material and mechanical flexibility. It is also important to confirm that the new cable will fit the existing festoon hardware and follow the same travel path without creating excessive tension or bending. Comparing the original cable specification or equipment documentation is the safest starting point.