cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V

Unshielded TFFN tray cable provides a compact 600V Type TC construction for industrial control and power circuits where space, routing flexibility and installation versatility are important. Its nylon-jacketed TFFN conductors help reduce overall cable diameter, making it a practical choice for conduit, cable tray, rack, direct burial and other installations where a smaller cable profile can simplify routing. Find additional configurations for industrial systems and equipment in our complete control cable product selection.

Showing 1–9 of 37 results

Search Part Number
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V

TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V

Array
(
    [0] => Applications:
  • TFFN Tray Cable is suitable for use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.
[1] => s:
  • TFFN Tray Cable is suitable for use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.
[2] => )
Applications:
  • TFFN Tray Cable is suitable for use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.

Item # Item Name Size (AWG/MCM) No. of Conductors Nominal Insulation Thickness (inches) Nominal Thickness Nylon (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Nominal Weight (LBS/MFT) RFQ
9401 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 2 (Flat) 0.015 0.004 0.045 0.195 x 0.297 49 Request a Quote
9402 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 3 0.015 0.004 0.045 0.310 66 Request a Quote
9403 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 4 0.015 0.004 0.045 0.340 79 Request a Quote
9404 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 5 0.015 0.004 0.045 0.370 94 Request a Quote
9405 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 6 0.015 0.004 0.045 0.400 109 Request a Quote
9406 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 7 0.015 0.004 0.045 0.400 118 Request a Quote
9408 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 9 0.015 0.004 0.045 0.460 147 Request a Quote
9409 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 10 0.015 0.004 0.045 0.480 162 Request a Quote
9411 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 12 0.015 0.004 0.045 0.510 202 Request a Quote

Construction

Conductors:

  • Stranded soft annealed copper.

Insulation:

  • 90°C polyvinyl chloride (PVC).

Insulation Jacket:

  • Applied directly over the PVC insulation is a tough nylon sheath offering protection to the insulation, type TFFN

Color Code:

  • Conductors are dual identified with color coding per ICEA Method 1, Table K-2 and alphanumeric printing per ICEA Method 4.

Cabling:

  • The specified number of conductors are cabled with fillers where needed. A suitable tape is applied over the assembly.

Applications:

  • TFFN Tray Cable is suitable for use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.

Rating:

  • 90°C Dry, 75°C Wet, 600 Volt

Features:

  • TFFN conductors allow for a small diameter cable.
  • Tough PVC jacket.
  • UL Listed as type TC, 600 Volts 90°C.
  • Meets IEEE 383 flame test with 70,000 BTU as well as 210,000 BTU Flame Source.
  • Moisture and sunlight resistant.
  • Meets appropriate sections of NEC articles 300, 318, 340, 501 and 725.
  • UL Listed for direct burial.

Frequently Asked Questions

TFFN conductors use thin PVC insulation with a protective nylon sheath, which helps create a compact cable construction.

Type TFFN conductors combine PVC insulation with a tough nylon outer covering applied directly over the insulation. This construction helps reduce the amount of insulation material required around each conductor compared with some other cable designs. The resulting smaller overall diameter can be useful where tray fill, conduit space or equipment routing is limited.

The nylon sheath provides added mechanical protection over the PVC conductor insulation.

Each conductor in this TFFN tray cable uses 90°C PVC insulation covered by a tough nylon sheath. The nylon layer helps protect the underlying insulation during handling, pulling and installation while allowing the conductor construction to remain relatively compact. This PVC-and-nylon combination is one of the defining characteristics of TFFN wire.

Yes, it may be used in certain Class I, Division 2 locations when installed in accordance with applicable NEC requirements.

This Type TC cable is identified for use in Class I, Division 2 hazardous locations under the applicable NEC provisions referenced by the manufacturer. Suitability still depends on the specific installation, equipment classification and local electrical requirements, so the complete system should be reviewed before specifying cable for a hazardous area.

Unshielded cable is generally appropriate when electromagnetic interference is not a significant concern for the circuit.

Shielding is typically added when sensitive signals may be affected by electrical noise from motors, drives, switching equipment or other nearby conductors. An unshielded TFFN tray cable can be a simpler and more economical option for power and control circuits where interference protection is not required by the system design. The electrical environment and signal sensitivity should be considered before deciding between shielded and unshielded constructions.

Direct-burial approval allows the cable to be used underground without requiring a raceway in applications where the installation permits it.

UL listing for direct burial gives designers and installers another routing option when portions of a control or power circuit must travel underground. This can simplify certain industrial or facility installations by eliminating the need for conduit along every underground section, provided the installation complies with applicable electrical codes and physical-protection requirements. The cable on this page is UL Listed for direct burial.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry