cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

THHN Tray Cable, Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V

Shielded THHN tray cable provides a 600V Type TC construction for industrial power and control circuits where protection from electrical interference is an important consideration. An overall aluminum Mylar shield with a copper drain wire helps manage electrical noise, while the PVC/nylon insulated conductors and PVC jacket support installations in cable tray, conduit, wireways and other demanding industrial environments.

Compare additional control cable and tray cable constructions for industrial power, control and signal applications.

Showing 1–9 of 42 results

Search Part Number
THHN Tray Cable, Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V

THHN Tray Cable, Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V

Array
(
    [0] => Applications:
  • For use in class 1, Division 2 Hazardous locations.
  • For installation in trays, wireways, ducts, conduit and aerially when properly supported by a messenger.
  • Approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required.
[1] => s:
  • For use in class 1, Division 2 Hazardous locations.
  • For installation in trays, wireways, ducts, conduit and aerially when properly supported by a messenger.
  • Approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required.
[2] => )
Applications:
  • For use in class 1, Division 2 Hazardous locations.
  • For installation in trays, wireways, ducts, conduit and aerially when properly supported by a messenger.
  • Approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required.

Item # Item Name Size (AWG/MCM) No. of Conductors Nominal Insulation Thickness (inches) Nominal Thickness Nylon (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Nominal Weight (LBS/MFT) RFQ
9401S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 2 0.015 0.004 0.045 0.299 62 Request a Quote
9402S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 3 0.015 0.004 0.045 0.314 80 Request a Quote
9403S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 4 0.015 0.004 0.045 0.340 94 Request a Quote
9404S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 5 0.015 0.004 0.045 0.416 109 Request a Quote
9406S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 7 0.015 0.004 0.045 0.447 132 Request a Quote
9408S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 9 0.015 0.004 0.045 0.509 162 Request a Quote
9411S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 12 0.015 0.004 0.060 0.584 220 Request a Quote
9414S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 15 0.015 0.004 0.060 0.635 262 Request a Quote
9418S THHN Tray Cable- Shielded-TYPE TC 90°C Wet, PVC/NYLON INSULATION - PVC JACKET- 600V 16 19 0.015 0.004 0.060 0.681 316 Request a Quote

Construction

Conductors:

  • Stranded Bare Copper Conductors.

Description:

  • Color coded polyvinyl chloride (PVC) Insulation with overall Nylon Sizes. 18 and 16 AWG are rated TFFN, Sizes 14, 12 and 10 are rated VN-THHN/THWN.
  • Conductors are cabled with fillers as needed.
  • Polyester binder tape.
  • Aluminum Mylar shield (100% coverage).
  • Stranded copper drain wire.
  • Black Polyvinyl Chloride (PVC) jacket.

Applications:

  • For use in class 1, Division 2 Hazardous locations.
  • For installation in trays, wireways, ducts, conduit and aerially when properly supported by a messenger.
  • Approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required.

Frequently Asked Questions

The aluminum Mylar shield helps reduce the effect of electromagnetic and radio-frequency interference on the conductors inside the cable.

Industrial environments often contain motors, variable frequency drives, switching equipment and other potential sources of electrical noise. This tray cable uses an aluminum Mylar shield with 100% coverage around the conductor assembly, creating a conductive barrier that can help limit interference from nearby electrical equipment. Shielding can be particularly useful where control circuits or other signals need additional protection from electrically noisy surroundings.

The drain wire provides a convenient electrical connection to the cable's shield.

The stranded copper drain wire runs in contact with the aluminum Mylar shield and provides a practical way to terminate or ground the shielding system as required by the installation design. This avoids having to make a direct connection to the thin foil shield itself and helps maintain a consistent electrical path for managing unwanted electrical noise. The appropriate grounding method should follow the equipment manufacturer's requirements and applicable electrical practices.

No. The conductor designation varies by wire size.

According to the product specifications, 18 and 16 AWG conductors are rated TFFN, while 14, 12 and 10 AWG sizes are rated VN-THHN/THWN. All use color-coded PVC insulation with an overall nylon covering, but the applicable conductor designation changes with size. This is an important detail to verify when specifying a particular gauge for an industrial control or power application.

Full foil coverage provides a continuous shielding layer around the cable's conductor assembly.

A 100% aluminum Mylar shield surrounds the cabled conductors, helping reduce gaps through which electrical interference could couple into the circuits. This construction is useful in installations where control wiring runs near motors, power conductors, drives or other equipment capable of generating electromagnetic noise. The amount of shielding required still depends on the sensitivity of the circuit and the electrical environment.

It can be used for industrial power and control applications when its conductor size, voltage rating and installation requirements match the circuit.

Type TC cable is used in a range of industrial electrical installations, and this 600V shielded construction is available in multiple conductor counts and wire sizes. That makes it suitable for many equipment power, control and auxiliary circuits where shielding is also beneficial. The proper configuration depends on circuit voltage, ampacity, conductor count, interference concerns and applicable electrical requirements.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry