cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V

Unshielded XHHW-2 tray cable provides a durable 600V Type TC solution for industrial control circuits requiring moisture-resistant crosslinked polyethylene insulation and a heavy-duty PVC outer jacket. Available in a broad range of conductor counts and sizes, this cable is suited for demanding installations where dependable electrical performance and flexible routing options are important.

Compare additional control cable and tray cable constructions for industrial systems requiring different insulation types, conductor configurations or shielding options.

Showing 1–9 of 54 results

Search Part Number
XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V

XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V

Array
(
    [0] => Application:
  • Control applications where cable is used in conduit, ducts, trays or racks. It can also be used in free air when supported by a messenger or for direct burial. Can be installed in cable trays per NEC Articles 318, 340 and 501.
[1] => :
  • Control applications where cable is used in conduit, ducts, trays or racks. It can also be used in free air when supported by a messenger or for direct burial. Can be installed in cable trays per NEC Articles 318, 340 and 501.
[2] => )
Application:
  • Control applications where cable is used in conduit, ducts, trays or racks. It can also be used in free air when supported by a messenger or for direct burial. Can be installed in cable trays per NEC Articles 318, 340 and 501.

Item # Item Name Size (AWG/MCM) No. of Conductors Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Nominal Weight (LBS/MFT) RFQ
9540 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 2 (Flat) 0.030 0.045 0.230 x 0.370 72 Request a Quote
9541 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 3 0.030 0.045 0.390 100 Request a Quote
9542 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 4 0.030 0.045 0.420 125 Request a Quote
9543 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 5 0.030 0.045 0.460 150 Request a Quote
9544 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 6 0.030 0.045 0.500 164 Request a Quote
9545 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 7 0.030 0.045 0.500 175 Request a Quote
9546 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 8 0.030 0.060 0.580 213 Request a Quote
9547 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 9 0.030 0.060 0.620 240 Request a Quote
9548 XHHW-2 Tray Cable Unshielded TYPE TC 90°C WET & DRY - 600V 14 10 0.030 0.060 0.640 260 Request a Quote

Construction

Conductors:

  • Stranded soft bare copper.

Insulation:

  • Concentric layer of 90°C cross linked polyethylene (XLP). This XLP compound is specially formulated to provide excellent electrical and physical properties. Each insulated conductor passes the UL VW-1 vertical flame test.

Color Code:

  • The individual conductors are color coded in accordance with ICEA Table K-2.

Cabling:

  • The specified number of conductors are cabled with fillers where needed and a suitable tape is applied over the assembly. Two-conductor cables are flat parallel design.

Overall Jacket:

  • A heavy-duty polyvinyl chloride (PVC) sheath to meet the requirements of UL Class-12 is applied over the assembled core.

Application:

  • Control applications where cable is used in conduit, ducts, trays or racks. It can also be used in free air when supported by a messenger or for direct burial. Can be installed in cable trays per NEC Articles 318, 340 and 501.

Features:

  • Moisture and sunlight resistant.
  • Meets UL 1277 flame tray test with 70,000 BTU flame source.
  • Rated 90°C Dry, 75°C Wet, 600 volt.
  • UL Listed as type TC and for aerial use and direct burial.
  • Insulated conductors are XHHW-2 type and pass VW-1 flame test
  • Meets appropriate sections of NEC Articles 318, 340 and 501.

Meets NEC:

  • Article 318 for Cable Tray Installations.
  • Article 340 for Cable Construction.
  • Article 501 for Class 1, Div. 2 Hazardous Locations.

Frequently Asked Questions

XHHW-2 insulation combines strong electrical properties with resistance to heat and moisture.

Each conductor uses a concentric layer of crosslinked polyethylene designed for demanding electrical environments. The thermoset insulation maintains its physical and electrical characteristics under elevated temperatures and provides the moisture resistance associated with XHHW-2 construction, making it well suited to industrial control cable applications.

This category includes a wide range of multi-conductor configurations for different control-circuit requirements.

Available products include two-conductor designs as well as cables with substantially higher conductor counts. This allows a single cable construction to support applications ranging from simple control circuits to equipment requiring numerous conductors within one overall jacket. The appropriate conductor count depends on the number of circuits or control points that need to be carried.

The flat arrangement provides a practical construction for cables containing only two insulated conductors.

Rather than adding fillers simply to create a round shape, the two conductors can be positioned side by side within the overall jacket. Cables with three or more conductors are cabled together with fillers where needed to form the assembled core. This allows the cable geometry to reflect the conductor count rather than forcing every configuration into the same shape.

Each insulated conductor has passed the UL VW-1 vertical flame test.

VW-1 testing evaluates how an individual insulated wire responds when exposed to a controlled vertical flame. In this tray cable, the XHHW-2 insulated conductors each meet that flame-performance requirement, while the complete cable construction also meets the UL 1277 tray-cable flame test.

The PVC jacket protects the insulated conductor assembly from moisture, sunlight and physical wear.

The overall sheath is designed to meet UL Class-12 requirements and provides a protective layer around the cabled conductors, fillers and binder. Combined with the XHHW-2 insulation, the jacket helps create a cable construction suited to industrial installations where the cable may be exposed to challenging environmental and mechanical conditions.