cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed

Showing all 7 results

Search Part Number
Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed

Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed

Stage and studio power setups need cable that can be moved, coiled, routed, and handled without slowing down the work. This extra-flex Type W cable group helps buyers compare portable single-conductor options by AWG size, strand count, insulation thickness, jacket thickness, outside diameter, current rating, and weight before requesting a quote for entertainment, production, or heavy-duty portable power applications.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Nominal O.D. (inches) Current (Amps) Nominal Weight (LBS/MFT) RFQ
21106 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 6 264/30 0.060 0.095 0.540 105 205 Request a Quote
21107 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 4 418/30 0.060 0.095 0.602 140 273 Request a Quote
21108 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 2 660/30 0.060 0.095 0.686 190 375 Request a Quote
21109 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 1 835/30 0.080 0.095 0.756 220 465 Request a Quote
21110 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 1/0 1056/30 0.080 0.095 0.805 260 549 Request a Quote
21111 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 2/0 1320/30 0.080 0.095 0.840 300 655 Request a Quote
21113 Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed 4/0 2090/30 0.080 0.095 0.985 405 960 Request a Quote

Conductor:

  • Extra flexible, 30 AWG Class "K" soft, annealed bare copper configured to provide superior flexing characteristics in portable applications in studios.

Insulation:

  • Ethylene propylene rubber with exceptional dielectric and mechanical properties. Rated 90° C, 2000 Volts, Has superior overload (130° C) and short circuit (250° C) protection high tensile strength and resistance to crushing and impact.

Jacket:

  • Black heavy-duty 90° C thermosetting chlorinated polyethylene (CPE) applied directly over an extra strength fiber cord. This open weave braided cord mechanically reinforces the jacket, helping it to retain cable configuration under severe stress conditions. This CPE formulation has superior resistance to crushing, abrasion, aging, weathering, ozone, water and chemicals.

Features:

  • UL Listed as "Type W" 2000 Volt 90° C.
  • Extra flexible 30 AWG Class "K" stranding.
  • Specially designed for studio set lighting and other theatre and entertainment applications.
  • Complies with applicable sections of NEC Articles 400, 520 and 530.
  • Meets flame test requirements of MSHA (Mine Safety and Health Administration) and Pennsylvania bureau of mines.
  • 90° C EP rubber for excellent electrical insulation.
  • Braid reinforced thermosetting jacket for outstanding performance and long life.
  • Water and sunlight resistant.

Applications:

  • Specially designed for portable applications in motion picture and television studies, theaters and other similar locations. The cable is recommended for use as supply conductors for portable stage lighting, portable switchboards and feeders, and other portable stage equipment, and to supply border lights when flexible conductors are required. It is suitable for extra hard use both indoors and out. The cable is also recommended for industrial applications where extra flexible, heavy duty. UL listed portable cable is needed.

Frequently Asked Questions

Stage lighting cable is flexible portable power cable used to supply electrical power to lighting equipment, portable switchboards, feeders, studio equipment, and other temporary or movable production systems. It is commonly used in theaters, motion picture studios, television studios, entertainment venues, and similar environments where cable may need to be moved, coiled, and rerouted.

The correct cable depends on voltage rating, current requirement, conductor size, flexibility, jacket durability, indoor or outdoor use, and project specifications.

Type W cable is used for stage lighting and production environments because it is designed for heavy-duty portable power applications. It can support flexible cable runs where power may need to be delivered to movable equipment, temporary lighting, feeders, or portable distribution systems.

For stage and studio use, buyers should confirm the required AWG size, amp rating, voltage rating, flexibility, jacket construction, and applicable project or safety requirements.

Extra flex refers to cable construction designed to handle frequent movement, bending, coiling, and handling. On this product group, the extra-flex construction is supported by fine-stranded Class K copper conductors, which help the cable remain flexible in portable applications.

Extra flexibility is important in production environments where cable may be installed, removed, stored, and reused frequently.

To choose the right size stage lighting cable, start with the current requirement, cable length, voltage rating, equipment load, and installation conditions. The product table can help compare AWG size, strand count, insulation thickness, jacket thickness, outside diameter, current rating, and cable weight.

For quote requests, provide the AWG size, required footage, current requirement, equipment use, and whether the cable will be used indoors, outdoors, temporarily, or in a repeated handling application.

Some stage lighting cable can be used outdoors when the specific construction is rated for the environment. Outdoor use may require resistance to water, sunlight, abrasion, weathering, and repeated handling.

Before ordering, confirm the cable’s rating, jacket material, temperature rating, voltage rating, current requirement, and whether the installation is temporary, portable, indoor, outdoor, or exposed to rough jobsite conditions.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry