Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.
Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.
Showing all 7 results

Stage and studio power setups need cable that can be moved, coiled, routed, and handled without slowing down the work. This extra-flex Type W cable group helps buyers compare portable single-conductor options by AWG size, strand count, insulation thickness, jacket thickness, outside diameter, current rating, and weight before requesting a quote for entertainment, production, or heavy-duty portable power applications.
| Item # | Item Name | Size (AWG/MCM) | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D. (inches) | Current (Amps) | Nominal Weight (LBS/MFT) | RFQ |
| 21106 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 6 | 264/30 | 0.060 | 0.095 | 0.540 | 105 | 205 | Request a Quote |
| 21107 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 4 | 418/30 | 0.060 | 0.095 | 0.602 | 140 | 273 | Request a Quote |
| 21108 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 2 | 660/30 | 0.060 | 0.095 | 0.686 | 190 | 375 | Request a Quote |
| 21109 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 1 | 835/30 | 0.080 | 0.095 | 0.756 | 220 | 465 | Request a Quote |
| 21110 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 1/0 | 1056/30 | 0.080 | 0.095 | 0.805 | 260 | 549 | Request a Quote |
| 21111 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 2/0 | 1320/30 | 0.080 | 0.095 | 0.840 | 300 | 655 | Request a Quote |
| 21113 | Stage Lighting Cable- Type W Extra Flex 90°C 2000V - UL Listed | 4/0 | 2090/30 | 0.080 | 0.095 | 0.985 | 405 | 960 | Request a Quote |
Conductor:
Insulation:
Jacket:
Features:
Applications:
Stage lighting cable is flexible portable power cable used to supply electrical power to lighting equipment, portable switchboards, feeders, studio equipment, and other temporary or movable production systems. It is commonly used in theaters, motion picture studios, television studios, entertainment venues, and similar environments where cable may need to be moved, coiled, and rerouted.
The correct cable depends on voltage rating, current requirement, conductor size, flexibility, jacket durability, indoor or outdoor use, and project specifications.
Type W cable is used for stage lighting and production environments because it is designed for heavy-duty portable power applications. It can support flexible cable runs where power may need to be delivered to movable equipment, temporary lighting, feeders, or portable distribution systems.
For stage and studio use, buyers should confirm the required AWG size, amp rating, voltage rating, flexibility, jacket construction, and applicable project or safety requirements.
Extra flex refers to cable construction designed to handle frequent movement, bending, coiling, and handling. On this product group, the extra-flex construction is supported by fine-stranded Class K copper conductors, which help the cable remain flexible in portable applications.
Extra flexibility is important in production environments where cable may be installed, removed, stored, and reused frequently.
To choose the right size stage lighting cable, start with the current requirement, cable length, voltage rating, equipment load, and installation conditions. The product table can help compare AWG size, strand count, insulation thickness, jacket thickness, outside diameter, current rating, and cable weight.
For quote requests, provide the AWG size, required footage, current requirement, equipment use, and whether the cable will be used indoors, outdoors, temporarily, or in a repeated handling application.
Some stage lighting cable can be used outdoors when the specific construction is rated for the environment. Outdoor use may require resistance to water, sunlight, abrasion, weathering, and repeated handling.
Before ordering, confirm the cable’s rating, jacket material, temperature rating, voltage rating, current requirement, and whether the installation is temporary, portable, indoor, outdoor, or exposed to rough jobsite conditions.
Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com