cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

ACSR Aluminum Conductor- Steel Reinforced

Showing 1–9 of 18 results

Search Part Number
ACSR Aluminum Conductor- Steel Reinforced

ACSR Aluminum Conductor- Steel Reinforced

Array
(
    [0] => Application:
  • Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
[1] => :
  • Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
[2] => )
Application:
  • Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Item # Item Name Code Name Size (AWG/MCM) Strand (Aluminum/Steel) Diameter Individual Wire Aluminum Inches Diameter Individual Wire Steel Inches Diameter Steel Core Inches Diameter Complete Cable Inches Weight Per 1000 Ft. (lbs) Rated Breaking Strength (lbs) RFQ
29800 ACSR Aluminum Conductor- Steel Reinforced Swan 4 6/1 0.0834 0.0834 0.0834 0.250 57.4 1,860 Request a Quote
29801 ACSR Aluminum Conductor- Steel Reinforced Swanate 4 7/1 0.0772 0.1029 0.1029 0.257 67.0 2,360 Request a Quote
29802 ACSR Aluminum Conductor- Steel Reinforced Sparrow 2 6/1 0.1052 0.1052 0.1052 0.316 91.3 2,850 Request a Quote
29803 ACSR Aluminum Conductor- Steel Reinforced Sparate 2 7/1 0.0974 0.1299 0.1299 0.325 105.7 3,640 Request a Quote
29804 ACSR Aluminum Conductor- Steel Reinforced Raven 1/0 6/1 0.1327 0.1327 0.1327 0.398 145.3 4,380 Request a Quote
29805 ACSR Aluminum Conductor- Steel Reinforced Quail 2/0 6/1 0.1489 0.1489 0.1489 0.447 183.0 5,300 Request a Quote
29806 ACSR Aluminum Conductor- Steel Reinforced Pigeon 3/0 6/1 0.1672 0.1672 0.1672 0.502 230.7 6,620 Request a Quote
29807 ACSR Aluminum Conductor- Steel Reinforced Penguin 4/0 6/1 0.1878 0.1878 0.1878 0.563 291.1 8,350 Request a Quote
29808 ACSR Aluminum Conductor- Steel Reinforced Waxwing 266.8 18/1 0.1217 0.1217 0.1217 0.609 289.5 6,880 Request a Quote

Construction

Conductor:

  • Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum-clad (AW).
  • Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Application:

  • Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Standards:

  • ASTM B-230 (Aluminum wire, 1350-H19 for electrical purposes).
  • ASTM B-231 (Aluminum conductors, Concentric-lay-stranded).
  • ASTM B-232 (Aluminum conductors, Concentric-lay-stranded, Coated steel reinforced [ACSR]).
  • ASTM B-341 (Aluminum-coated steel core wire for aluminum conductors, Steel reinforced [ACSR/AZ]).
  • ASTM B-498 (Zinc-coated steel core wire for aluminum conductors, steel reinforced [ACSR/AZ]).
  • ASTM B-500 (Zinc-coated and aluminum coated stranded steel core for aluminum conductors, steel reinforced [ACSR]).

Frequently Asked Questions

ACSR stands for aluminum conductor steel reinforced. It refers to a bare overhead conductor with aluminum strands for electrical conductivity and a steel core for added mechanical strength.

This construction is commonly used when a conductor needs to carry current while also handling tension across overhead spans.

ACSR cable is used for overhead utility lines, transmission lines, distribution systems, service applications, and line construction projects. It is commonly selected where the cable needs a balance of conductivity, strength, span performance, and durability.

The right ACSR conductor depends on the required size, stranding, strength, weight, ampacity, and project design.

ACSR combines aluminum conductor strands with a steel reinforcing core. All-aluminum conductor does not include the steel reinforcement.

ACSR is often chosen when added tensile strength is needed for longer spans, higher tension, or overhead line designs where sag control is important. All-aluminum conductor may be used where steel reinforcement is not required.

To choose the right ACSR conductor, start with the project specification and line design requirements. Important details include AWG or MCM size, code name, aluminum and steel stranding, outside diameter, weight, rated breaking strength, span length, tension, sag limits, and ampacity requirements.

For quote requests, it helps to provide the code name or size, stranding, quantity, required footage, and any applicable utility or engineering specification.

ACSR code names identify specific conductor constructions and sizes. Names such as Swan, Sparrow, Raven, Quail, Pigeon, Penguin, and Waxwing are used to distinguish ACSR conductors with different AWG or MCM sizes, aluminum and steel stranding, diameters, weights, and rated breaking strengths.

Using the correct code name helps ensure the quoted conductor matches the required line design and project specification.