cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Overhead Distribution Copper Cable Service Drop

Showing 10–18 of 21 results

Search Part Number
Overhead Distribution Copper Cable Service Drop

Overhead Distribution Copper Cable Service Drop

Array
(
)
Conductors Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. Neutral is solid or stranded, bare hard drawn copper.

Item # Item Name Code Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Neutral Messenger- Hard Drawn size (AWG) Neutral Messenger- Strand (AWG) Current (Amps) Nominal Weight (LBS/MFT) Voltage rating (volts) RFQ
29518 Overhead Distribution Copper Cable Service Drop Tuscan 3/0 19 0.055 3/0 7 287 1632 600 Request a Quote
29520 Overhead Distribution Copper Cable Service Drop Composite 4/0 19 0.055 4/0 7 335 2057 600 Request a Quote
29550 Overhead Distribution Copper Cable Service Drop Atlanta 6 7 0.045 6 1 89 381 600 Request a Quote
29552 Overhead Distribution Copper Cable Service Drop Tallahassee 6 7 0.045 6 7 89 381 600 Request a Quote
29554 Overhead Distribution Copper Cable Service Drop Baton Rouge 4 7 0.045 4 1 117 588 600 Request a Quote
29556 Overhead Distribution Copper Cable Service Drop Richmond 4 7 0.045 4 7 117 588 600 Request a Quote
29558 Overhead Distribution Copper Cable Service Drop Jackson 2 7 0.045 2 1 158 913 600 Request a Quote
29560 Overhead Distribution Copper Cable Service Drop Seattle 2 7 0.045 2 7 158 913 600 Request a Quote
29562 Overhead Distribution Copper Cable Service Drop Nashville 1/0 19 0.055 1/0 7 214 1415 600 Request a Quote

Conductors
Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. Neutral is solid or stranded, bare hard drawn copper.

Description:

  • The conductors are Class B strand, bare soft drawn copper insulated with heat and moisture resistant cross-linked polyethylene. The neutral is solid or stranded, bare hard drawn copper

Industry Approvals:

  • ASTM B-1 (Hard Drawn).
  • ASTM B-3 (Soft Drawn or Annealed).
  • ASTM B-8 (Concentric-lay strand).
  • ICEA S66-524.
  • Conductor rated at 90° C

Frequently Asked Questions

Copper service drop cable may be specified when the project requires higher conductivity, compatibility with copper service equipment, reduced conductor diameter, or a utility-approved copper conductor for the overhead service connection.

Conductor material affects current capacity, cable weight, connection requirements, voltage drop, and long-term compatibility with terminals or service equipment. Copper and aluminum service drop cables should not be treated as direct one-for-one substitutions without checking the full project requirements.

Important conditions include span length, exposure to weather, service load, point of attachment, clearance requirements, conductor configuration, and the equipment or utility standard that governs the service connection.

Yes, copper service drop cable may be used for replacement service work when it matches the existing system requirements, utility rules, service rating, and connection equipment. The replacement cable should be selected based on the full service design, not only the previous cable size.

Buyers should provide the service type, conductor size, number of conductors, voltage rating, span details, required length, utility specification if available, and whether the cable is for a new overhead service, replacement service, or project-specific distribution connection.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry