cable

Where Inventory Meets Expertise

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.

Find the Products You Need Fast.

Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.

Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.

Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V

Selecting SHD-GC cable for shovel and dragline service involves more than matching voltage and conductor size. Cable diameter, grounding configuration, strand construction, and compatibility with the equipment’s reel and connections can all affect the right choice. Custom Cable Corp. can help buyers compare available configurations for replacement or new-equipment requirements. Explore our complete selection of mining cable for additional mining power and equipment cable options.

Showing 1–9 of 36 results

Search Part Number
Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V

Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V

Array
(
    [0] => Applications:
  • Suitable applications include power supply cables to open pit, strip and deep mines. Also to provide power to shovels, dredges, cranes and drag lines. They can be used in wet or dry locations and are rated 90°C for continuous conductor temperature.
[1] => s:
  • Suitable applications include power supply cables to open pit, strip and deep mines. Also to provide power to shovels, dredges, cranes and drag lines. They can be used in wet or dry locations and are rated 90°C for continuous conductor temperature.
[2] => )
Applications:
  • Suitable applications include power supply cables to open pit, strip and deep mines. Also to provide power to shovels, dredges, cranes and drag lines. They can be used in wet or dry locations and are rated 90°C for continuous conductor temperature.

Item # Item Name Size (AWG/MCM) Strands Nominal Insulation Thickness (inches) Nominal Jacket Thickness (inches) Ground Wire (2)(AWG/MCM) Ground Ground wire strand Ground Check(AWG) Nominal O.D. (inches) Current (Amps) RFQ
25540 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 6 133 0.070 0.155 10 49 10 1.290 93 Request a Quote
25541 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 4 133 0.070 0.155 8 49 10 1.400 122 Request a Quote
25542 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 2 133 0.070 0.170 6 133 8 1.590 159 Request a Quote
25543 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 1 133 0.080 0.190 5 133 8 1.760 184 Request a Quote
25544 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 1/0 259 0.080 0.190 4 133 8 1.860 211 Request a Quote
25545 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 2/0 259 0.080 0.205 3 133 8 2.000 243 Request a Quote
25546 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 3/0 259 0.080 0.205 2 133 8 2.130 279 Request a Quote
25547 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 4/0 259 0.080 0.220 1 133 8 2.310 321 Request a Quote
25548 Shovel and Drag Line Cable TYPE SHD-GC - 2000, 5000, 8000 AND 15000 V 250 427 0.095 0.220 1/0 259 6 2.510 355 Request a Quote

Construction

Conductors:

  • Tinned annealed copper. Each wire positively positioned in the strand to distribute stress evenly and provide longer flex life.

Strand Shield:

  • Extruded semi-conducting shield minimizes formation of harmful ozone and helps distribute stress evenly to provide a longer life.

Insulation:

  • Ethylene propylene rubber. Rated for 90°C. Has superior overload (130°C) and short circuit (250°C) protection.

Shield:

  • Tinned copper braid over color-coded semi-conducting tape (on 5KV and above).
  • Increases safety, helps distribute stress more evenly and inhibits formation of harmful ozone.

Ground Wires:

  • Tinned copper positioned in the interstices to ground the shields.

Ground Check Wires:

  • Stranded bare copper insulated with ethylene propylene rubber.

Conductor Identification:

  • The colors are black, white and red. The grounding conductors are uninsulated and the ground check conductor is yellow.

Reinforcing Braid:

  • Textured fiber composition cord. An extra strength fiber cord which helps retain cable configuration under severe crushing and stress.

Jacket:

  • Reinforced double pass extra heavy-duty hypalon®. This jacketing is tough, durable and highly flexible. It has superior resistance to crushing, abrasion, compression, impact, chemicals, water, aging, weathering and harmful ozone. Colors other than black are available on special order.

Applications:

  • Suitable applications include power supply cables to open pit, strip and deep mines. Also to provide power to shovels, dredges, cranes and drag lines. They can be used in wet or dry locations and are rated 90°C for continuous conductor temperature.

Industry Approvals:

  • Reinforced extra heavy-duty Hypalon® Jacket.
  • Extra flexible tinned copper conductors.
  • Rated 2KV, 5KV, 8KV or 15KV. 90°C continuous.
  • Excellent flame resistance.
  • MSHA and Penna. Division of mine safety accepted.
  • Braided tinned copper shields for flexing service.

Standards:

  • Designed and constructed in accordance with ICEA-NEMA standards. (ICEA Publication No. S-68-516 and NEMA Publication No. WC8).

Frequently Asked Questions

SHD-GC identifies a shielded, heavy-duty portable power cable that includes a ground-check conductor.

This construction is designed for demanding power applications where equipment may move during operation and grounding integrity is especially important. The ground-check feature distinguishes SHD-GC from similar cable constructions that do not include a dedicated conductor for the ground-monitoring circuit.

The ground-check conductor allows a compatible monitoring system to verify continuity of the equipment grounding path.

Rather than carrying normal equipment power, the ground-check conductor works as part of the electrical protection system. If the monitored grounding circuit is interrupted, the system can identify the loss of continuity and respond according to the equipment and protection design.

SHD-GC cable is intended for heavy-duty portable or trailing service, while mine power feeder cable is generally used to deliver power to mine distribution or load centers.

The distinction is important when cable will be connected to equipment that moves, reels, or changes position during operation. A feeder installation and a trailing-cable application can have very different mechanical, grounding, and flexibility requirements even when their system voltages are similar.

Cable diameter can affect compatibility with reels, couplers, glands, equipment openings, and cable-handling systems.

Two cables with similar conductor sizes or voltage ratings may not have identical outside diameters. When replacing an existing shovel or dragline cable, checking the nominal O.D. can help prevent fit problems with existing equipment and connection hardware.

No. Voltage rating and current-carrying capacity describe different cable requirements.

The voltage rating indicates the electrical system class for which the cable construction is designed. Current capacity is influenced by factors such as conductor size, cable construction, operating conditions, and installation. Buyers should therefore match both the required voltage class and ampacity rather than assuming a higher-voltage cable automatically supports a larger electrical load.

Popular Categories

Discover our most requested cable types used across multiple industries.

What Our Client Says

quote2
quote2
Speak with a wire and cable specialist today

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com

Can’t find what you’re looking for?

Product Enquiry