Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
At Custom Wire & Cable, every product line is backed by the same principle: deliver the best wire for the job and stand behind it. We combine deep industry knowledge with supply-chain efficiency to help clients meet tight schedules without compromising quality.
Our inventory covers virtually every electrical and electronic cable application imaginable. We maintain over 15,000 active SKUs, each engineered for performance, consistency, and compliance with UL, CSA, and RoHS standards. From heat-resistant wire to precision coaxial and multi-conductor control cable, we supply the materials that keep manufacturing, communications, and energy systems running 24/7.
Browse our full range of wire and cable products by category. Each product is clearly specified to help you quickly identify the right solution for your application.
Type CMP, c(UL)PCC multi-paired individually foil shielded plenum cable is designed for low-voltage signal and communication applications where separate shielding helps reduce interference between pairs. Available in 22 AWG, 2-pair and 3-pair constructions, it is suited for plenum spaces where CMP-rated cable is required. Explore additional plenum cable options for other shielded and unshielded configurations.
Showing all 2 results

Array ( )
| Item # | Item Name | Size (AWG/MCM) | No pairs | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D. (inches) | Nominal capacitance between conductors pfft | Nominal capacitance between one conductor and other conductors connected sheilds pfft | RFQ |
| 11555 | Type CMP, c(UL)PCC Multi Paired Individually Foil Shielded Plenum Cable | 22 | 2 | 7/30TC | 0.006 | 0.010 | 0.147 | 28.0 | 50.4 | Request a Quote |
| 11556 | Type CMP, c(UL)PCC Multi Paired Individually Foil Shielded Plenum Cable | 22 | 3 | 7/30TC | 0.006 | 0.010 | 0.184 | 28.0 | 50.4 | Request a Quote |
Construction
Conductor:
Features:
Insulation:
Shields:
Jacket:
Approvals:
Packaging:
Individual pair shielding helps isolate each signal pair from electrical interference and from signals carried by adjacent pairs.
This construction can be useful in applications where multiple low-voltage signals share the same cable and maintaining separation between circuits is important. Each pair has its own foil shield and drain wire rather than relying on a single shield around the entire cable.
The number of pairs should match the number of separate circuits or signal paths required by the system.
A 2-pair construction may be appropriate when two independent pairs are needed, while a 3-pair cable provides an additional pair within the same overall cable. The correct configuration depends on the connected equipment, circuit design and project specifications.
Yes. Individually shielding each twisted pair can help reduce unwanted signal interaction between adjacent pairs.
The combination of twisted conductors and separate foil shields provides additional isolation within the cable. This can be useful for sensitive communication, signaling, control or monitoring circuits where electrical noise or crosstalk could affect performance.
It may be installed in a plenum space above a suspended ceiling when the space and application require a CMP or compatible plenum-rated cable.
Not every area above a ceiling is automatically considered a plenum. The building design, air-handling system, applicable electrical code and project specifications determine whether a plenum-rated cable is required.
Confirm the required conductor size, number of pairs, voltage rating, shielding configuration, plenum rating and applicable system requirements.
It is also important to verify whether the project requires a particular UL classification, temperature rating or installation method. Matching the cable construction to both the electrical requirements and the installation environment helps avoid specifying more or less cable protection than the system needs.
Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can contact us via: info@gmail.com
